Vextral Systemscommunity tools
ProtoCall ToolsLOCAL-FIRST
Founding test group

PROTOCALL TOOLS / 01

Make the numbers
mean something.

A local-first workbench for the decisions between an industrial endpoint, a network and the person trying to commission both.

01 / INDUSTRIAL VALUE WORKBENCH

ProtoCall Mapper

Normalise the address. Decode the bytes. Keep a mapping you can hand over.

01

Where is the value?

The tool never guesses whether a vendor document is using a human register reference or the protocol offset.

For holding registers, the first human reference is 40001.

02

How is it stored?

Paste decimal or hexadecimal 16-bit register values. Separate them with spaces or commas.

03

How should it read?

Apply a simple engineering calculation after the protocol value is decoded.

LOCAL WORKING SET

Mapping ledger 0

+

Add a decoded value above to start a local mapping sheet. Nothing is sent to a server.

THE TOOL ATLAS

One workbench. Clear homes for each field question.

Mitsubishi stays a dedicated strength. The same clear, offline-capable approach then expands across platforms, networks and OPC UA.

MITSUBISHI & GX WORKS

Make Mitsubishi data layouts explicit.

The field-proven Simple Comms Toolkit becomes a clearer, local-first workbench for GX Works and link-register work.

  1. 02

    PLC Mapping Planner

    Decimal / hex ranges, W-bit to M mapping and K4M block boundaries.

    Open
  2. 03

    Simple CPU Comms Table

    Build device mappings with protocol defaults, block sizing and collision checks.

    Open
  3. 04

    GX Works File Check

    Inspect or round-trip the UTF-16 mapping export before it reaches the PLC project.

    Open

CROSS-PLATFORM PROTOCOL & DATA

Interpret what arrived before changing a thing.

The protocol questions repeat across vendors: address conventions, register layout, conversion, polling and evidence.

  1. 01

    ProtoCall Mapper

    Compare every byte and word order, then retain the working interpretation locally.

    LIVE · OFFLINE-CAPABLE
  2. 05

    Poll Planner

    Budget cycle time, timeout and device count before a one-second task drifts into seconds.

    Open
  3. 06

    Controller Address Helpers

    Start with Modbus, EtherNet/IP and S7 address conventions rather than vendor-specific guesswork.

    Open

NETWORK & OPC UA

Give OT and IT the same answer.

Small, transparent calculators for the endpoint, port and certificate decisions that otherwise become long troubleshooting calls.

  1. 07

    IP to Hex

    Already live inside the PLC Mapping Planner for function-block inputs; it moves here as the network quick-tool set grows.

    Open
  2. 08

    IPv4 Range Planner

    Calculate subnet, usable range, gateway checks and broadcast address without an online lookup.

    Open
  3. 09

    Endpoint & Certificate Doctor

    Compare the listener endpoint with OPC UA URI and certificate host checks locally.

    Open